V9 and later will no longer support Windows Operating Systems prior to Windows 10.

07/12/2024

10.7.1

New
Support N2 customers

06/05/2024

10.6.6

Improved
Support PFC-6006 firmware upgrades

05/22/2024

10.5.82

New
IntelliCom SIA configuration
Improved
Hide unused IntelliCom account field
Improved
Default to all IntelliCom signals selected

04/04/2024

10.4.124

New
Added Fire Service Access Elevator (FSAE) zones and point functions.
Fixed
Resolved potential issue when opening a panel configuration file from an email attachment.
Improved
Increase allowed User Codes to 250
Improved
Increase allowed Audio Patterns to 293
Improved
Increase allowed Audio Messages to 1000
Improved
Decrease Audio Pattern Row height by about 20%
Improved
A new panel configuration will default to the Time Zone of the PC.
Improved
Added warning that amplifiers will be changed to dual channel which switching from single channel audio system to a dual channel.
Improved
Made order of items in the Point Types drop down and Point Type selection menu consistent.
Improved
Added zone number and point address to various locations in the zone configuration.

01/02/2024

10.3.95

New
Allow Guest to Add IntelliCom

12/04/2023

10.2.94

Fixed
A VM-1000 attached to an AFC-1000 could not be configured under certain circumstances

11/01/2023

10.2.93

Fixed
Limit audio patterns to 255

10/25/2023

10.2.92

New
Added support for Wheelock T4 Sync
Improved
Various quality of life improvements

08/01/2023

10.1.45

New
Support IntelliCom
New
Support password protection for panel configuration files
Improved
Various quality of life improvements

05/22/2023

9.1.364

Fixed
Guest registration error

04/27/2023

9.1.363

New
Added general setting for the network audio port
New
Added audit error is network paging zone configured and no VM-1000
New
Added network page zone style
New
Added network paging override alarm setting
New
Enabled Ethernet settings for all VM-1000s
New
Only allow reference points of style network paging in network paging zones
New
Support auto update for future versions of the tools
Fixed
DACR report correctly generates reports when the format is set to "SIA-Limited"
Improved
Loading time for application improved when unable to connect to Internet
Improved
Removed dialer options pertaining to answering the phone for remote programming

12/05/2022

9.0.375.0

09/08/2022

9.0.372.0

New
Support for all time zones

07/25/2022

9.0.366.0

New
Ability to export point list. File > Create Point Report
New
Ability to Open file from and Save files to IntelliView
New
Output activation delay max setting increased from 600 to 900 seconds
New
Support for Windows 10 and 11 only. Support for older operating systems has been removed.
New
Removed capability to transfer the panel program via modem.
Fixed
Previously, when the user clicks on a panel in the network and then clicks back to the Network Setup tab each time the user clicks back to the Network Setup tab another copy of a panel will be added when the user Uploads and Adds a panel. So if the user clicks back and forth between network setup and a panel tab 5 times than 6 copies of a panel will be added when they perform an upload and add panel.
Fixed
The workaround either to close and reopen the configuration before uploading and adding a panel or to delete the extra copies of the panel.
Improved
New color scheme
Improved
Removed audit error when type Contact Input Disable Outputs assigned to a zone type of Alert
Improved
When configuring central station reporting, if the configuration is set to report multiple panels through one panel (either using MC-1000 modules or networked panels) for Contact ID by point, generate an Audit Warning. This will allow the configuration to be sent to the panel(s). Previously, this configuration generated an Audit Error and prevented downloading the configuration to the panel.

02/28/2022

8.1.2.0

Improved
Allow configuring multiple IPA-4000V panels (or multiple AFC-1000V panels) in a single building. Previously user was only allowed to configure a single panel with a VM-1000 per building.
Improved
Allow the CO sensor in the PAD-PCD (split) configuration to be added to a supervisory zone.

11/23/2021

8.0.669.0